Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Scand J Clin Lab Invest ; 80(2): 156-161, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31841042

RESUMEN

Sepsis is the most frequent cause of death in the intensive care unit (ICU). A rapid and correct diagnosis and initiation of therapy is crucial for improving patient outcomes. The aim of this study was to compare the performance of calprotectin with the more widely used sepsis biomarker procalcitonin (PCT) in ICU patients. The performance of calprotectin and PCT as sepsis and prognostic markers for 30-d mortality was compared in a prospective, observational study in an eight-bed ICU. We investigated concentrations of the biomarkers in plasma collected at admission from all ICU patients admitted during a year (2012-2013, n = 271) together with simplified acute physiology 3 scores (SAPS3) and sequential organ failure assessment (SOFA) scores. The receiver operating characteristic (ROC) analysis showed a higher area under the curve (AUC) value for calprotectin (0.79) than for PCT (0.49) when used as a sepsis marker. The calprotectin concentrations at admission were higher in non-survivors than in survivors at day 30. In our study, calprotectin was superior to PCT for distinguishing between ICU patients with sepsis and non-sepsis patients. Calprotectin also had higher predictive ability regarding 30-d mortality.


Asunto(s)
Biomarcadores/sangre , Complejo de Antígeno L1 de Leucocito/sangre , Polipéptido alfa Relacionado con Calcitonina/sangre , Sepsis/sangre , Sepsis/mortalidad , Adulto , Anciano , Anciano de 80 o más Años , Mortalidad Hospitalaria , Humanos , Unidades de Cuidados Intensivos/estadística & datos numéricos , Persona de Mediana Edad , Puntuaciones en la Disfunción de Órganos , Pronóstico , Estudios Prospectivos , Curva ROC , Suecia/epidemiología , Heridas y Lesiones/sangre , Heridas y Lesiones/mortalidad , Adulto Joven
2.
Clin Lab ; 63(9): 1493-1496, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28879709

RESUMEN

BACKGROUND: Fecal calprotectin measurement is generally recommended to exclude inflammatory bowel disease (IBD) in patients with suspected IBD. A problem with the fecal calprotectin assays so far has been the rather long test-turnaround times. Recently a particle enhanced turbidimetric immunoassay (PETIA) for fecal calprotectin with assay times of approximately 10 minutes has been introduced on the European market. The aim of this study was to define reference intervals for adults with this new fecal calprotectin PETIA using two different extraction methods. METHODS: Samples were collected from 382 healthy individuals from the Swedish CArdioPulmonary bioImage Study (SCAPIS) Uppsala cohort in the age range 50 - 65 years. 202 samples were processed with CALEX® Cap extraction device (BÜHLMANN, Schönenbuch, Switzerland) and 180 samples were extracted using weighed samples. The extracted samples were analyzed on a Mindray BS-380 using the fCal Turbo PETIA reagent (BÜHLMANN). RESULTS: The calculated reference values for the Calex device were < 199 µg/g for the whole cohort, < 184 µg/g for females, and < 215 µg/g for males, while the corresponding values for weighed samples were < 153 µg/g for the whole cohort, < 141 µg/g for females, and < 215 µg/g for males. There were no significant statistical differences for calprotectin levels in males and females. CONCLUSIONS: The CALEX device yielded slightly higher calprotectin values. As there were no significant gender differences, the study indicates gender independent reference intervals of < 199 µg/g feces for the CALEX device and < 153 µg/g feces for weighed samples in patients in the 50 - 65 year age range.


Asunto(s)
Heces/química , Complejo de Antígeno L1 de Leucocito/análisis , Adulto , Anciano , Biomarcadores , Estudios de Cohortes , Ensayo de Inmunoadsorción Enzimática , Femenino , Humanos , Enfermedades Inflamatorias del Intestino/diagnóstico , Masculino , Persona de Mediana Edad , Valores de Referencia
3.
Clin Lab ; 63(5): 907-913, 2017 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-28627817

RESUMEN

BACKGROUND: Fecal calprotectin assays are widely used in diagnosis and monitoring of inflammatory bowel disease (IBD) in patients with suspected IBD. The most frequently used technique is ELISA and microtiter plates. Turbidimetric assays for analysis of fecal calprotectin can significantly reduce turnaround time. Many laboratories may be reluctant to run fecal samples on their large chemistry analyzers. The aim of this study was to evaluate fecal calprotectin particle enhanced turbidimetric immunoassay (PETIA) on smaller chemistry analyzers that could be dedicated for fecal samples. METHODS: The BÜHLMANN fCAL® turbo assay was validated on two table top chemistry analyzers, Mindray BS-200E and cobas® c111. RESULTS: The assay was linear in the range between 20 and 1,900 µg/g with a limit of quantification around 20 µg/g on both instruments. The total coefficient of variation was < 7% in the range between 50 and 1,300 µg/g on both instruments. No antigen excess hook effect was observed up to 18,000 µg/g on the Mindray BS-200E and up to 20,000 µg/g on cobas® c111. The BÜHLMANN fCAL® turbo assay showed a high correlation with the BÜHLMANN fCAL® ELISA. CONCLUSIONS: Running the BÜHLMANN fCAL® turbo on Mindray BS-200E or cobas® c111 chemistry analyzers can provide rapid test results without exposing large routine chemistry analyzers to stool samples.


Asunto(s)
Complejo de Antígeno L1 de Leucocito/análisis , Nefelometría y Turbidimetría , Biomarcadores , Heces/química , Humanos , Enfermedades Inflamatorias del Intestino/diagnóstico
4.
Scand J Clin Lab Invest ; 77(1): 15-18, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27768851

RESUMEN

Hemoglobin A1c (HbA1c) is a frequently requested laboratory test and there is thus a need for high throughput instruments for this assay. We evaluated a new automated multicapillary zone electrophoresis instrument (Capillarys 3 Tera, Sebia, Lisses, France) for analysis of HbA1c in venous samples. Routine requested HbA1c samples were analyzed immunologically on a Roche c6000 instrument (n = 142) and then with the Capillarys 3 Tera instrument. The Capillarys 3 Tera instrument performed approximately 70 HbA1c tests/hour. There was a strong linear correlation between Capillarys 3 Tera and Roche Tina-Quant HbA1c Gen 3 assay (y = 1.003x - 0.3246 R2 = .996). The total CV for the 12 capillaries varied between 0.8 and 2.2% and there was a good agreement between duplicate samples (R2 = .997). In conclusion, the Capillarys 3 Tera instrument has a high assay capacity for HbA1c. It has a good precision and agreement with the Roche Tina-Quant HbA1c method and is well suited for high volume testing of HbA1c.


Asunto(s)
Electroforesis Capilar/normas , Hemoglobina Glucada/análisis , Hemoglobinometría/normas , Automatización de Laboratorios/instrumentación , Electroforesis Capilar/instrumentación , Hemoglobinometría/instrumentación , Humanos , Inmunoensayo/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
J Clin Apher ; 25(5): 287-93, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20806415

RESUMEN

Cellsorba™ is a medical device for leukocytapheresis (LCAP) treatment of ulcerative colitis (UC). Cellsorba™ EX Global type has been developed from Cellsorba E for intended use with ACD-A as anticoagulant. We evaluated safety and efficacy of the modified Cellsorba using ACD-A in a pilot trial comprising patients with active UC, despite receiving 5-ASA. A total of 10 LCAP treatments/patients were administered. Safety assessment focused on clinical signs and symptoms, hematological variables, as well as levels of bradykinin and IL-6. Efficacy was determined using the Mayo clinical/endoscopic scoring index as well histological assessment of biopsies. Additional aim was to evaluate the impact of apheresis system lines and filter on selected regulatory molecules. All six subjects completed the trial without any serious adverse events. WBC, platelet counts, and levels of bradykinin and IL-6 were not significantly affected. The median Mayo score decreased from 8.0 to 3.5 at week 8 (and to 2 at week 16 for the responders). Four patients were responders, of whom two patients went into remission. Median histological scores decreased from 3.5 to 2.0 in these four patients. Concentration of LL-37 increased within the apheresis system lines. LCAP with Cellsorba EX using ACD-A as anticoagulant was found to be a safe and well-tolerated procedure in patients with active UC. The positive impact on efficacy parameters merits further evaluation in a controlled fashion.


Asunto(s)
Anticoagulantes/uso terapéutico , Ácido Cítrico/uso terapéutico , Colitis Ulcerosa/terapia , Glucosa/análogos & derivados , Leucaféresis/instrumentación , Adolescente , Adulto , Péptidos Catiónicos Antimicrobianos/sangre , Ligando CD30/sangre , Femenino , Glucosa/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Seguridad , Catelicidinas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...